首页 / 院系成果 / 成果详情页

Computed Tomography-Guided Interstitial Brachytherapy for Locally Advanced Cervical Cancer: Introduction of the Technique and a Comparison of Dosimetry With Conventional Intracavitary Brachytherapy  期刊论文  

  • 编号:
    422e1d5b-86ba-4bb8-bac8-d471bb26fb71
  • 作者:
    Liu, ZhongShan#[1]Guo, Jie[1];Zhao, YangZhi(赵杨祉)[2]Lin, Xia[1];Zhang, BingYa[1];Zhang, Chu[1];Wang, HongYong[1];Yu, Lei[1];Ren, XiaoJun[1];Wang, TieJun*[1]
  • 语种:
    英文
  • 期刊:
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER ISSN:1048-891X 2017 年 27 卷 4 期 (768 - 775) ; MAY
  • 收录:
  • 关键词:
  • 摘要:

    Objective We present a new technique of 3-dimensional computed tomography-guided interstitial (IS) brachytherapy (BT) for locally advanced cervical cancer, offering a more advantageous clinical treatment approach.
    Materials/Methods Interstitial BT was performed using an applicator combining uterine tandem and metal needles; needles were inserted freehand under real-time 3-dimensional computed tomography guidance. Twenty-eight patients with bulky tumors and/or parametrial extension (tumor size > 5 cm) after external beam radiotherapy received IS BT. Dosimetric outcomes of the IS BT including the total dose (external beam radiotherapy and high dose-rate BT) D90 for the high-risk clinical target volume (HR-CTV) and D2cc for the organs at risk (OARs) were investigated and compared with a former patient group consisting of 30 individuals who received the conventional intracavitary (IC) BT.
    Results The mean D90 values for HR-CTV in the IC BT and IS BT groups were 76.9 5.7 and 88.1 +/- 3.3 Gy, respectively. Moreover, 85.7% of the patients received D90 for HR-CTV of 87 Gy or greater in the IS BT group, and only 6.7% of the patients received D90 for HR-CTV of 87 Gy or greater in the IC BT group. The D2cc for the bladder, rectum, and sigmoid were 84.7 +/- 6.8, 69.2 +/- 4.2, and 67.8 +/- 4.5 Gy in the IC BT group and 81.8 +/- 6.5, 66.8 +/- 4.0, and 64.8 +/- 4.1 Gy in the IS BT group. The mean number of needles was 6.9 +/- 1.4, with a mean depth of 2.9 +/- 0.9 mm for each IS BT. Interstitial BT was associated with only minor complications.
    Conclusions The IS BT technique resulted in better dose-volume histogram parameters for large volume tumors (>5 cm) compared with the conventional IC BT and acceptable risk of acute complications in locally advanced cervical cancer and is clinically feasible.

  • 推荐引用方式
    GB/T 7714:
    Liu Zhong-Shan,Guo Jie,Zhao Yang-Zhi, et al. Computed Tomography-Guided Interstitial Brachytherapy for Locally Advanced Cervical Cancer: Introduction of the Technique and a Comparison of Dosimetry With Conventional Intracavitary Brachytherapy [J].INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER,2017,27(4):768-775.
  • APA:
    Liu Zhong-Shan,Guo Jie,Zhao Yang-Zhi,Lin Xia,&Wang Tie-Jun.(2017).Computed Tomography-Guided Interstitial Brachytherapy for Locally Advanced Cervical Cancer: Introduction of the Technique and a Comparison of Dosimetry With Conventional Intracavitary Brachytherapy .INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER,27(4):768-775.
  • MLA:
    Liu Zhong-Shan, et al. "Computed Tomography-Guided Interstitial Brachytherapy for Locally Advanced Cervical Cancer: Introduction of the Technique and a Comparison of Dosimetry With Conventional Intracavitary Brachytherapy" .INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER 27,4(2017):768-775.