首页 / 院系成果 / 成果详情页

Analysis of factors that affect the precision of the radiographic lateral femoral bowing angle using a three-dimensional computed tomography-based modelling technique  期刊论文  

  • 编号:
    4939bd3a-ab6f-405c-9bb9-b6e6b1a9edee
  • 作者:
  • 语种:
    英文
  • 期刊:
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH ISSN:1749-799X 2017 年 12 卷 ; JUN 14
  • 收录:
  • 关键词:
  • 摘要:

    Background: Precise measurement of lateral femoral bowing is important to achieve postoperative lower limb alignment. We aimed to investigate factors that affect the precision of the radiographic lateral femoral bowing (RLFB) angle using three-dimensional (3D) models and whether the angle affects surgery design.
    Methods: Forty femurs in total were divided into two groups based on their preoperative RLFB angle. The flexion contracture angle, preoperative and postoperative RLFB angles, and intersection angle between the mechanical and anatomical axes were compared. The angle between the arc and sagittal planes, varus and valgus angles, and intersection angle between the mechanical and anatomical axes were measured on a 3D model.
    Results: There was no significant between-group difference in 3D model measurements of the angle between the arc and sagittal planes (p = 0.327). There was no significant difference between the mechanical and anatomical axes measured by both imaging modalities (p > 0.258). When the RLFB was > 5 degrees, the flexion contracture angle and radiographic femoral bowing angle were positively correlated (r = 0.535, p < 0.05). Distal femur varus and valgus angles significantly differed between the two groups (p = 0.01). After total knee arthroplasty, the radiographic femoral bowing angle decreased significantly. When the cases" radiographic femoral bowing angle is larger and the angle between the arc and sagittal planes is smaller as measured in 3D models, the angle between the arc and coronal planes is larger.
    Conclusion: The radiographic femoral bowing angle does not reflect the actual size of lateral femoral bowing, does not greatly affect surgery design, and is greatly affected by flexion contracture deformity. A RLFB angle larger than 15 degrees indicates real lateral femoral bowing.

  • 推荐引用方式
    GB/T 7714:
    Li Ye-Ran,Gao Yu-Hang,Qi Xin, et al. Analysis of factors that affect the precision of the radiographic lateral femoral bowing angle using a three-dimensional computed tomography-based modelling technique [J].JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH,2017,12.
  • APA:
    Li Ye-Ran,Gao Yu-Hang,Qi Xin,Liu Jian-Guo,&Li Shu-Qiang.(2017).Analysis of factors that affect the precision of the radiographic lateral femoral bowing angle using a three-dimensional computed tomography-based modelling technique .JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH,12.
  • MLA:
    Li Ye-Ran, et al. "Analysis of factors that affect the precision of the radiographic lateral femoral bowing angle using a three-dimensional computed tomography-based modelling technique" .JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH 12(2017).