Changes of Load Distribution on Cup-Bone Interface at the Different Positions of Non-Cemented Acetabular Cup  会议论文 期刊论文  

  • 编号:
    7b8f0a75-d475-4234-bd49-097a0abed21d
  • 作者:
  • 语种:
    英文
  • 期刊:
    MATERIALS ENGINEERING FOR ADVANCED TECHNOLOGIES (ICMEAT 2013) ISSN:1660-9336 2014 年 510 卷 (297 - +) ; 2014
  • 收录:
  • 关键词:
  • 摘要:

    Objective To explore the relationship between acetabular cup position and the load distribution within the acetabulum and to confirm an optimal range of cup position, thereby providing a theoretical criterion from a biomechanical aspect for proper cup implantation in clinical work. Methods A male adult cadaveric pelvic was scanned with spiral CT, and then the two-dimensional images were evaluated using GE medical systems software and the outline of the pelvis was identified by the edge detective estimation. Pelvic coordinate data were put into the computer to build up a three-dimensional (3D) finite element model of the pelvic using Solidworks software. A phi 48 non-cemented cup from Tianjin Huabei Medical Instrument Factory was used, and the 3D measurement of the cup was carried out by CLY single-arm 3D measurement apparatus, which was made in Testing Technology Institute of China. The measurement data were transferred into computer. Through the CAD Sliod Works 2010 software, the 3D model of the cup was automatically reconstructed. After wards, one-foot standing position was simulated to conduct the loading and constraint of the model, the Mises and shear force distributing of the cup were analyzed, forecasting the mechanical risk of prosthetic failure. Results In the 3D finite element model of human pelvis, the number of total nodes was 103043 and the number of total elements was 69271. Abduction angle did not affect the Mises and shear force distributions between the range of 40 degrees-50 degrees(P>0.05). However, significant affects appeared in Mises and shear force once the abduction angle was < 35 degrees or > 50 degrees. The change of the cup anteversion within 5 degrees-30 degrees would not affect the Mises and shear forces in the acetabulum (P > 0.05). Conclusion A uniform load distribution on the cup-bone interface can be obtained when the cup abduction angle is from 40 degrees to 50 degrees. The change of the cup anteversion angle can not affect the load distribution in the acetabulum, therefore the cup abduction range of 40 degrees-50 degrees can be confirmed as the safe range for cup implantation.

  • 推荐引用方式
    GB/T 7714:
    Li Dongsong,Li Shuqiang,Cai Bo, et al. Changes of Load Distribution on Cup-Bone Interface at the Different Positions of Non-Cemented Acetabular Cup [J].MATERIALS ENGINEERING FOR ADVANCED TECHNOLOGIES (ICMEAT 2013),2014,510:297-+.
  • APA:
    Li Dongsong,Li Shuqiang,Cai Bo,Feng Wei,&Liu Jianguo.(2014).Changes of Load Distribution on Cup-Bone Interface at the Different Positions of Non-Cemented Acetabular Cup .MATERIALS ENGINEERING FOR ADVANCED TECHNOLOGIES (ICMEAT 2013),510:297-+.
  • MLA:
    Li Dongsong, et al. "Changes of Load Distribution on Cup-Bone Interface at the Different Positions of Non-Cemented Acetabular Cup" .MATERIALS ENGINEERING FOR ADVANCED TECHNOLOGIES (ICMEAT 2013) 510(2014):297-+.
  • 条目包含文件:
    文件类型:PDF,文件大小:
    正在加载全文
浏览次数:28 下载次数:0
浏览次数:28
下载次数:0
打印次数:0
浏览器支持: Google Chrome   火狐   360浏览器极速模式(8.0+极速模式) 
返回顶部