首页 / 院系成果 / 成果详情页

Finite Element Analysis of Acetabular Medial Wall Displacement Osteotomy in Adult Acetabular Dysplasia  会议论文 期刊论文  

  • 编号:
    b046835e-8a92-4aa0-a75c-f8f90d17cd2a
  • 作者:
    Li DongSong(李冬松)#*[1]Li ShuQiang[1];Cai Bo[2];Yang Chen[1];Liu Jian Guo[1];
  • 语种:
    English
  • 期刊:
    MECHANICAL ENGINEERING AND MATERIALS, PTS 1-3 ISSN:1660-9336 2012 年 152-154 卷 (1353 - +)
  • 收录:
  • 关键词:
  • 摘要:

    Objective To look for a suitable displacement range of acetabular medial wall following osteotomy by computer-aided design finite element analysis. Methods Solid Works 2008 software was used to establish three-dimensional models of acetabular dysplasia pelvis. Acetabular medial wall displacement osteotomy was simulated to make acetabular medial wall bone displace from 2 mm bone contact to 7 mm bone contact in the pelvic cavity. One experimental group was set at 1 mm intervals, totally 10 experimental groups. The acetabulum in each group was split into four quadrants. The prosthesis acetabulum-bone interface in each group was analyzed by computer simulation contrast mechanics experiment. The Mises stress and shear stress values were measured between acetabular prosthesis and bone interface. Results In groups 1, 5, 6, 9 and 10, the Mises stress was unevenly distributed in posterior inferior, anterior superior and anterior inferior quadrants. In groups 2, 3, 4, 7 and 8, the Mises stress was evenly distributed in posterior inferior, anterior superior and anterior inferior quadrants. Of them, the stress was most even in the group 4. In groups 2, 3, 4, 7 and 8, the shear stress was evenly distributed in the above-mentioned three quadrants. The shear stress was lowest in the groups 7 and 8. These indicate that joint force in the acetabulum mainly focused in the posterior superior quadrant. With the displacement of acetabular cup, the contact area of acetabular cup and bone would gradually increase, which finally increased the Mises stress in the contact surface. However, shear stress decreased with displacement of acetabular medial wall. Conclusion the suitable displacement range of acetabular medial wall osteotomy is 1 mm away from the pelvic cavity and 1 mm complete embolism in the pelvic cavity. The optimal position was 1 mm complete embolism in the pelvic cavity.

  • 推荐引用方式
    GB/T 7714:
    Li DongSong,Li ShuQiang,Cai Bo, et al. Finite Element Analysis of Acetabular Medial Wall Displacement Osteotomy in Adult Acetabular Dysplasia [J].MECHANICAL ENGINEERING AND MATERIALS, PTS 1-3,2012,152-154:1353-+.
  • APA:
    Li DongSong,Li ShuQiang,Cai Bo,Yang Chen,&Liu Jian Guo.(2012).Finite Element Analysis of Acetabular Medial Wall Displacement Osteotomy in Adult Acetabular Dysplasia .MECHANICAL ENGINEERING AND MATERIALS, PTS 1-3,152-154:1353-+.
  • MLA:
    Li DongSong, et al. "Finite Element Analysis of Acetabular Medial Wall Displacement Osteotomy in Adult Acetabular Dysplasia" .MECHANICAL ENGINEERING AND MATERIALS, PTS 1-3 152-154(2012):1353-+.
  • 条目包含文件:
    文件类型:PDF,文件大小:
    正在加载全文
浏览次数:8 下载次数:0
浏览次数:8
下载次数:0
打印次数:0
浏览器支持: Google Chrome   火狐   360浏览器极速模式(8.0+极速模式) 
返回顶部